PC015-ES CO₂ Seal-off Laser System: Precision Engineering for Advanced Clinical Results CO2 (Sealed-off) Fractional Laser Surgical System PC015-ES The Model PC015-ES is a professional-grade 15W CO₂ laser platform, meticulously engineered to bridge the gap between surgical precision and aesthetic ...

Product Details
Highlight:

CO2 surgical laser machine

,

PC015-ES surgical laser machine

,

Pulsed laser machine for surgery

Spot Size: Adjustable, 0.1 Mm To 2 Mm
Control Interface: Touchscreen Panel
Wavelength: 10.6 Micrometers
Power Supply: AC 110-240V, 50/60Hz
Power Output: Up To 30 Watts
Laser Type: Carbon Dioxide (CO2) Laser
Weight: Approximately 35 Kg
Operation Mode: Continuous Wave And Pulsed
Safety Features: Emergency Stop Button, Key Switch, Safety Goggles Included
Applications: Dermatology, ENT, Gynecology, Dentistry, General Surgery
Cooling System: Integrated Air Cooling
Beam Delivery: Articulated Arm Or Flexible Fiber
Product Description
PC015-ES CO₂ Seal-off Laser System: Precision Engineering for Advanced Clinical Results

CO2 (Sealed-off) Fractional Laser Surgical System PC015-ES

The Model PC015-ES is a professional-grade 15W CO₂ laser platform, meticulously engineered to bridge the gap between surgical precision and aesthetic excellence. Utilizing a high-stability sealed-off glass tube source and a refined TEM00 beam mode, the system ensures a consistent, high-density energy focus ($le 0.2mm$) for superior tissue interaction. Clinicians can leverage the synergy of Fractional and Super Pulse technologies to perform bloodless incisions or deep tissue remodeling while significantly reducing thermal relaxation time. Designed for longevity and global adaptability, the PC015-ES represents a reliable investment for modern medical practices seeking to optimize patient recovery and treatment safety.


Technical Specifications
Feature Detailed Specifications
Model PC015-ES
Laser Type Sealed-off CO₂ Laser ($10,600nm$)
Laser Source Industrial-grade Glass Tube
Output Power 15W (Stable Output)
Emission Mode TEM00 (Gaussian Beam for maximum precision)
Operation Modes Super Pulse, Repeat Pulse, Continuous Wave (CW)
Min. Pulse Width 0.02s (Super Pulse Mode)
Spot Diameter $le 0.2mm$ at focal point
Delivery System 7-Joint, Spring-Balanced Articulated Arm (110cm Radius)
Aiming Beam 650nm Diode Laser ($le 3mW$)
Cooling System Integrated Closed-Cycle Water Cooling
Electrical 120 VAC / 60Hz or 220 VAC / 50Hz (Global Compatible)
Weight / Size 35 Kg / $88 times 88 times 88 cm$

Key Advantages & Clinical Applications
  • Expert-Level Precision (TEM00): The high-quality transverse mode (TEM00) ensures the laser energy is concentrated in a perfect Gaussian spot, allowing for cleaner cuts and more predictable ablation depths.

  • Minimal Thermal Trauma: Advanced Super Pulse technology delivers high peak power in ultra-short bursts (0.02s), vaporizing tissue faster than heat can conduct to surrounding areas, which minimizes downtime and post-op redness.

  • Ergonomic Maneuverability: The 7-joint articulated arm provides weightless 360° movement with a 110cm reach, allowing the surgeon to maintain extreme accuracy during prolonged procedures without fatigue.

  • Sealed-off Longevity: The "Sealed-off" design protects the CO₂ gas purity, ensuring a long service life and stable power output with virtually zero gas-related maintenance.

  • Global Reliability: Built with a dual-voltage power supply and a high-efficiency closed-cycle water cooling system, the PC015-ES is designed for continuous operation in high-volume clinics worldwide.

  • Versatile Clinical Scope:

    • Dermatology: Precision skin resurfacing, scar revision, and benign lesion removal.

    • Surgery: Bloodless cutting, vaporization of soft tissue, and effective coagulation.


Product Q&A (Trust & Authority)

Q: How does the PC015-ES ensure patient safety during high-power treatments?

A: Safety is inherent in the Super Pulse mode, which allows for "cold ablation"—vaporizing the target tissue so quickly that the surrounding skin remains below the threshold of thermal damage. Furthermore, the 650nm aiming beam allows the practitioner to visualize the exact treatment spot before firing.

Q: What is the maintenance requirement for the closed-cycle cooling system?

A: The system is designed for low maintenance. Because it is a closed-cycle water cooling system, it prevents internal contamination and ensures the laser source stays at an optimal temperature, extending the life of the glass tube compared to air-cooled alternatives.

Q: Is the 15W power sufficient for both superficial and deep tissue work?

A: Yes. In CO₂ laser surgery, the quality of the beam (TEM00) and the spot size ($le 0.2mm$) are more critical than raw wattage. The 15W output focused into a tiny spot creates a high energy density capable of both delicate resurfacing and effective surgical excision.

Q: What is the logistics and warranty policy for international orders?

A: Every unit is shipped in a robust wooden case to prevent calibration shifts during transit. We provide a 1-year warranty and have a typical lead time of 5–10 working days, ensuring your practice can integrate this technology with minimal delay.